Electric Meter
ArchiCAD Talk Depository | 13434009013D parametric, Electric Meter, with meter and pole setting
-
UNIT CONVERT
ArchiCAD Talk Depository | 13434004022D parametric length and area converter
-
T0025 - Meter, Radiation Survey
|Radiation survey meter. Characteristics/components include hand held and battery operated with a built-in detector; and ability to detect alpha, beta, gamma and x-ray radiation. This unit is used for spot-checking laboratories and other work areas for contamination of equipment, counter tops and floors. The unit is also well suited for detecting accidental exposures to personnel clothes, checking x-ray equipment for possible leakage or locating small spills.
-
JS 1,6-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 1,6-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-G1-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 4-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 1,6-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 1,6-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-G1-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 4-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 1,6-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 1,6-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-G1-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 4-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 1,6-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 1,6-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-03 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-G1-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 4-02 SMART+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 1,6-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 1,6-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-G1-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 4-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-G1-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 4-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 1,6-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 4-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 1,6-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 2,5-G1-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS90 4-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 2,5-G1-02 SMART C+ Vane-Wheel Single-Jet Dry Water Meter with Radio Module AT-WMBUS-16-2
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters SMART C+ in standard version are equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing and they are adapted to operation in the systems of remote data transfer (AMR).
-
JS 1,6 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS90 1,6 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS 1,6-03 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS 2,5 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS 2,5-03 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS 2,5-G1 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS 4 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS90 1,6-03 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS90 2,5 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS90 2,5-03 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS90 2,5-G1 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS90 4 -NK; -NKP Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 90 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP). In standard version they are equipped with five-barrel counter (IP65), antimagnetic protection SN + and brass housing. Possible operation of water meters in the systems of remote readings transfer.
-
JS 6,3 MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 6,3 MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 6,3 -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 6,3/165 MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 6,3/165 -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10-G1 ¼ MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10-G1 ¼ -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10 MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10 -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 16 MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 16 -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 6,3 -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 10-G1 ¼ MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 10-G1 ¼ -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 10 MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 10 -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 16 MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS130 16 -NK; -NKP MASTER+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of warm water with a temperature up to 130 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master + are equipped with impulse transmitter (JSNK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing, antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 6,3 MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 6,3 -NK; -NKP MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10-G1 ¼ MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10-G1 ¼ -NK; -NKP MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10 MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 10 -NK; -NKP MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 16 MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
JS 16 -NK; -NKP MASTER C+ Vane-Wheel Single-Jet Dry Water Meter
|For measuring the flow and volume of water with a temperature up to 30 °C or 50 °C in the closed-circuit system with the full flow of the flux, and on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H) and in vertical or horizontal hoses with the counter directed sidewards (V). Water meters JS Master c+ are equipped with impulse transmitter (JS-NK) or adapted for installation of the transmitter (JS-NKP), in standard version with five-barrel counter (IP65), brass housing with antimagnetic protection. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 40 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 40 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 40 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 50 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 50 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 50-G Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 50-G -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 65 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 65 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 80 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 80 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 100 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 100 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 125 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 125 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 150 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 150 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 200 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 200 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 250 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 250 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 300 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 300 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 40 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 50 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 50-G Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 50 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 50-G -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 65 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 65 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 80 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 80 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 100 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 100 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 125 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 125 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 150 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 150 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 200 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 200 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 250 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 250 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 300 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN130 300 -NK; -NKP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of hot water with a temperature up to 130 °C, on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
UL 2,5 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 2,5-1 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
ELF 0,6 Compact Heat Meter with Flow Transducer Type JS90-NI
|Precise and reliable heat meter, equipped with high class heat calculator and flow transducer of class 2, with electronic detection of rotor rotation and archiving many of data readings. It is distinguished by its modern design. Heat meter for measuring the consumption of heat energy drawn from heat networks by small residential or office buildings. Heating factor with a temperature up to 90 °C (105 °C - when installing the heat meter on a return pipe) and maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), or in vertical hoses (V).
-
UL 4 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 4-1 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 6,3 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 10 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
ELF 1 Compact Heat Meter with Flow Transducer Type JS90-NI
|Precise and reliable heat meter, equipped with high class heat calculator and flow transducer of class 2, with electronic detection of rotor rotation and archiving many of data readings. It is distinguished by its modern design. Heat meter for measuring the consumption of heat energy drawn from heat networks by small residential or office buildings. Heating factor with a temperature up to 90 °C (105 °C - when installing the heat meter on a return pipe) and maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), or in vertical hoses (V).
-
ELF 1,5 Compact Heat Meter with Flow Transducer Type JS90-NI
|Precise and reliable heat meter, equipped with high class heat calculator and flow transducer of class 2, with electronic detection of rotor rotation and archiving many of data readings. It is distinguished by its modern design. Heat meter for measuring the consumption of heat energy drawn from heat networks by small residential or office buildings. Heating factor with a temperature up to 90 °C (105 °C - when installing the heat meter on a return pipe) and maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), or in vertical hoses (V).
-
ELF 1,5 (DN20) Compact Heat Meter with Flow Transducer Type JS90-NI
|Precise and reliable heat meter, equipped with high class heat calculator and flow transducer of class 2, with electronic detection of rotor rotation and archiving many of data readings. It is distinguished by its modern design. Heat meter for measuring the consumption of heat energy drawn from heat networks by small residential or office buildings. Heating factor with a temperature up to 90 °C (105 °C - when installing the heat meter on a return pipe) and maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), or in vertical hoses (V).
-
ELF 2,5 Compact Heat Meter with Flow Transducer Type JS90-NI
|Precise and reliable heat meter, equipped with high class heat calculator and flow transducer of class 2, with electronic detection of rotor rotation and archiving many of data readings. It is distinguished by its modern design. Heat meter for measuring the consumption of heat energy drawn from heat networks by small residential or office buildings. Heating factor with a temperature up to 90 °C (105 °C - when installing the heat meter on a return pipe) and maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), or in vertical hoses (V).
-
MWN 400 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 400 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 500 Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
MWN 500 -NK; -NO; -NKO; -NKOP Nubis Propeller Water Meter (Woltman) with Horizontal Rotor Axis
|For measuring of consumption of greater amounts of cold water with a temperature up to 30 °C or 50 °C on the maximum working pressure up to 16 bar (PN16). Suitable for installation in the horizontal hoses (pipelines) with the counter directed upwards (H), in vertical or horizontal hoses with the counter directed sidewards (V) or in diagonal hoses (H/V). MWN water meters in standard version are equipped with six-barrel counter (IP65, IP68 – optional) and painted cast-iron housing. Water meters are adapted to operation in the systems of remote data transfer (AMR).
-
L1950 - Demineralizer, Water, Floor Mounted
|Floor mounted water demineralizer. The unit has a one half to three gpm capacity. It has two beds, automatic calibration, purity meter, recirculation pump and disposable cartridges. The system continuously recirculates to discourage growth. Used to produce high purity water for laboratory use. May also be wall mounted.
-
M0630 - Anesthesia Apparatus, 3 Gas
|Three gas anesthesia apparatus. Basic unit consists of steel cabinet with casters with one shallow, one medium, and one deep drawer, seven long scale eleven-inch flowmeters, five cylinder yokes, and telescoping absorber post. It includes two-canister model carbon dioxide absorber with inhalation and exhalation check valves, switch valve, switch valve elbow, sidearm Vernitrol, flow calculator, mounting kit, ventilator calculator, ventilator and an oxygen piping inlet. Also features nitrous oxide fail safe valve kit, aspirator kit, gas evacuator with vacuum and a flow meter safety cover. Used to dispense a mixture of gases during surgical procedures.
-
M7723 - Electroencephalograph, 32 Channel
|32 channel electroencephalograph. Unit consists of a cart, regulated power supply, a chart drive, an input cable, a master electrode selector, a monitor, electronic data storage devices, a computer and a plastic stimulator. Unit features fully automatic or manual operation, photic stimulation and a built-in impedance meter. The unit is designed for maximum efficiency in recording and performing encephalographic studies. The system offers a full range of electrode selection and programmed protocols. This is an advanced diagnostic unit for use in neurology clinics.
-
FAAC J355 HA M30-P1 Hydraulic Automatic bollard
|FAAC J355 HA M30-P1 bollard is certified for the use in perimeter security; it has been purposely designed for the protection of sensitive areas, such as airports embassies, consulates, banks, harbors, etc. FAAC J355HA-M30-P1 bollard has been tested according to the American standards “ASTM F 2656-07 - Standard Test Method for Vehicle Crash Testing of Perimeter Barriers”, obtaining thus the certification for the highest penetration rate. The class M30-P1 indicates that FAAC J355 HA M30-P1 bollard is able to stop a 6800kg truck at a speed of 50Km/h (=30M/h) in 1 meter (P1). J355 HA M30-P1 main features are: 1. Tested according to ASTM F 2656-07 2. Integrated Hydraulic Unit concept 3. Kept lock in up position also in the event of power failure 4. Extreme care in the material selection 5. Rapid and silent movements
-
FAAC J355 HA M30-P1 EFO Hydraulic Automatic bollard - Emergency Fast Operation
|FAAC J355 HA M30-P1 Emergency Fast Operation (EFO) bollard is certified for the use in perimeter security; it has been purposely designed for the protection of sensitive areas, such as airports embassies, consulates, banks, harbors, etc. FAAC J355HA-M30-P1 EFO bollard has been tested according to the American standards “ASTM F 2656-07 - Standard Test Method for Vehicle Crash Testing of Perimeter Barriers”, obtaining thus the certification for the highest penetration rate. The class M30-P1 indicates that FAAC J355 HA M30-P1 bollard is able to stop a 6800kg truck at a speed of 50Km/h (=30M/h) in 1 meter (P1). Emergency Fast Operation device (EFO) guarantees a very rapid rising speed (1.5s) to increase the offered protection. J355 HA M30-P1 EFO main features are: 1. Tested according to ASTM F 2656-07 2. Integrated Hydraulic Unit concept 3. Kept lock in up position also in the event of power failure 4. Extreme care in the material selection 5. Rapid and silent movements 6. Very quick emergency rising (1.5s)
-
Coat and hat rack 65
|Thanks to its clean design our most popular coat and hat rack. With the wall mounted Coat and Hat Rack 65 or 65K with hanging rail you can create a modified cloakroom system for both private and public spaces. Its available in any length of your choosing. The material is nickel plated steel or powder coated paint in different colors to harmonize with the surrounding environment. Coat and hat rack 65 comes with ten anchor hooks per meter where you can hang jackets and coats.