-
UNIT CONVERT
ArchiCAD Talk Depository | 13434004022D parametric length and area converter
-
M4800 - Urodynamic Measurement System w/Video
|Urodynamic measurement system. Unit consists of uroflowmeter to measure urinary flow, urethral pressure profilometer to measure urethral pressure, multi-channel cystometer to measure bladder capacity and response, and electromyographic recording to measure sphincter and other muscle activity. It includes a LCD monitor, a desktop PC, color printer, and automatic calibration. System is designed to evaluate the storage and transportation of urine in the urinary tract and the cause of abnormal voiding (urination).
-
L1115 - Analyzer, Hematology, Differential, Automatic
|Automatic hematology counter/analyzer. The analyzers characteristics/components include the measurement of eight hematology parameters as well as platelet counts, auto-rinse cycle between analysis, minimum specimen requirement of 100 microliters, readout results in 40 seconds, automatic calibration and capable of computerized differential counting and manual verification of results. Used for hematology analysis.
-
L1182 - Refractometer
|Refractometer. Characteristics/ components include an accommodation of liquids, solids, solids-in-liquids and powders, temperature measured at interface of samples, photosensors measurement, automatic calibration, multi-channel programming, an accuracy of +/-.0001 refractive unit and automatic temperature compensation. Used for glucose and urine refractive indexes.
-
L1185 - Analyzer, Glucose
|Discrete glucose analyzer. Characteristics include sample volume of 10 microliters, measurement principle of the oxygen rate method, throughput of 67 samples per hour and a glucose value displayed in mg/dl. This is a self contained system with automatic fill and drain cycles. Used for glucose analysis of serum plasma or saliva samples
-
L1190 - Osmometer
|Osmometer. Characteristics/components include semi-automatic operation, measurement of osmodality of 0.2ml samples, accuracy to (+/-) 0.5%, temperature controlled liquid freezing bath, flow-through cell assembly and high speed testing capability. Used to determine precise concentration of solute particles for urines, urea, free water clearances, electrolyte studies, serum and other applications.
-
L1930 - Analyzer, pH/Blood Gas
|PH/blood gas analyzer. The unit measures pH, PCO2 and P02 and performs calculations for CO2, HCO3, and base excess. Characteristics of the unit include: an automatic calibration capability and measurement ranges of 6.4 to 8.0 for pH; 0 to 800 mmHg for PO2; and 8.0 to 200.mmHg. for PCO2. Used in laboratories to conduct pH/blood gas determinations.
-
L1931 - Analyzer, Blood Gas
|Blood/gas analyzer. The unit measures for pH, PO2, and PCO2 using a standard sample of 90 microliters or greater. A measurement range of 6.4 to 8.0 for pH, 8 to 200mmHg for PCO2 and 0 to 800 mmHg for PO2 is accommodated by the unit. Used in laboratories to measure blood gas parameters of patient samples. System to provide for the measurement of: pH, pCO2, pO2, BP, tHb, NA+, K+, and CL-, or CA++. Calculated values to include: tCO2, O2 Saturation, CT, HCO3 (actual and standardized), BE (vv and vt) and Hct.
-
M5705 - Gauge, Distance, Pupillary
|Pupillary distance gauge. Unit is electronic and features corneal reflection, LCD display, 0.5mm measurement increments, and measure fixation PD distance to 30 cm from infinity. Unit runs on battery power and is designed to measure the distance between pupils as well as corneal and pupil diameter.
-
X2100 - Scanner, Ultrasound, General Purpose
|High definition, diagnostic ultrasound system for Radiology, Cardiology, Vascular, ob-gyn, Perinatology, and Surgical imaging applications. The unit employs curved, phased and linear array imaging technology. The system supports colorflow, pulse and continuous wave imaging modalities. On board software measurement packages available for all imaging applications. The system is DICOM 3.0 compatible, for easy linkage to filmless image management systems and review stations. In addition, a full line of probes and conventional recording devices are available.
-
X2105 - Scanner, Ultrasound, Cardiac (Echo)
|High definition, diagnostic ultrasound system for Radiology, Cardiology, Vascular, ob-gyn, Perinatology, and Surgical imaging applications. The unit employs curved, phased and linear array imaging technology. The system supports colorflow, pulse, continuous wave imaging modalities. On board software measurement packages available for all imaging applications. The system is DICOM 3.0 compatible, for easy linkage to filmless image management systems and review stations. In addition, a full line of probes and conventional recording devices are available.
-
Mipolam Symbioz
|MIPOLAM SYMBIOZ™ is a fully flexible homogeneous compacted floorcovering in sheet, 2m wide, abrasion group T, providing excellent resistance to wear and tear in high traffic areas. Its weight is 2580 gr/m². It features a non directional design incorporating coloured chips to ensure an even colour throughout the thickness presenting a nice matt finish. MIPOLAM SYMBIOZ™contains over 75% sustainable or renewable raw materials. It includes a 100% bio based plasticizer, made of residues from cereals (wheat, corn…). This floorcovering is a non emissive product (below the level of VOC measurement accuracy).
-
Colonnade Conference
|The Colonnade table was designed by Poul Christiansen and Boris Berlin. The inspiration is visible in the leg system that carries a 12mm compact laminate table top. Colonnade is a refined table system for meeting a number of shapes and over 30 standard sizes. It is available with integrated cable well (C-box) that facilitates the latest in technology. The system has organic and soft shapes, beautiful and functional, yet anonymous expression. Table top in 12 mm compact laminate with black core. Other sizes / geometries on request. Colonnade is available with or without C-Box. C-box contains 4 el. sockets, 4 data connectors, 2 USB connectors, 1 HDMI connectors, 1 VGA connectors, 1 audio connectors. Outside measurement are 62x16,5 cm. C-box is only sold along with a Fora Form table Table sold complete.
-
Rome Conference Table
|The Rome Conference table takes the best of two worlds, the stylish base of the Colonnade table and 25mm self-supporting MDF plates. The table top is ideal for customization in shape, surfaces and sizes. The table with its light expression is a furnishing friendly design suitable to many kinds of chairs and setups. The Rome conference tables can be supplied with integral cable well (C-box) that facilitates the latest of technology. The table comes with U-Base leg system. The Rome Conference table is designed by Komplot Design. Table top in 25mm MDF white HPL laminate with sloping profile and grey side list in ABS plastic (RAL 7012). or: Table top in 25mm MDF light gray HPL laminate with sloping profile and grey side list in ABS plastic similar to laminate with rounded corners. Other sizes / geometries on request. Rome Conference is available with or without C-Box. C-box contains 4 el. sockets, 4 data connectors, 2 USB connectors, 1 HDMI connectors, 1 VGA connectors, 1 audio connectors. Outside measurement are 62x16,5 cm. C-box is only sold along with a Fora Form table Table sold complete. Base in molded high polished aluminum. Adjustable plastic gliders. Dimensions: 480x120 cm H: 72 cm 360x120 cm H: 72 cm 240x120 cm H: 72 cm 180x120 cm H: 72 cm Other sizes / geometries on request.
-
Next Conference Table
|The Next conference tables range from small meeting rooms to large conference rooms. The table, with its light expression makes the design furnishing friendly and fits different types of chairs and setups. Next Conference tables are available with integrated cable well (C-box) that facilitates the latest in technology. The table design is ideal for customization in shape, surfaces and sizes. The design of the base, facilitates easy cleaning. The Next Conference Table is designed by Torsteinsen Design. Table top in 25mm MDF white HPL laminate with sloping profile and grey side list in ABS plastic (RAL 7012). or: Table top in 25mm MDF light gray HPL laminate with sloping profile and grey side list in ABS plastic similar to laminate with rounded corners. Other sizes / geometries on request. Next Conference is available with or without C-Box. C-box contains 4 el. sockets, 4 data connectors, 2 USB connectors, 1 HDMI connectors, 1 VGA connectors, 1 audio connectors. Outside measurement are 62x16,5 cm C-box is only sold along with a Fora Form table Table sold complete. Base in polished stainless steel. T-leg or corner legs. Next no.11 with T-foot, use X-leg as center column. Adjustable plastic gliders. Dimensions: 240x120 cm H: 72 cm 300x120 cm H: 72 cm Other sizes / geometries on request.
-
HEWI Panic bar to EN 1125 PS111XA10
|System 111 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Handle made of stainless steel, diameter 25 mm with tubular handle made of polyamide, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side, conforms to the requirements of DIN 18040. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 27.7 mm, width of the transmission unit 45 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS111XA10
-
HEWI Panic bar to EN 1125 PS111XA20
|System 111 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Handle made of stainless steel, diameter 25 mm with tubular handle made of stainless steel, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 27.7 mm, width of the transmission unit 45 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS111XA20
-
HEWI Panic bar to EN 1125 PS111XA30
|System 111 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Version for BKS-locks. Handle made of stainless steel, diameter 25 mm with tubular handle made of polyamide, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side, conforms to the requirements of DIN 18040. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 32 mm, width of the transmission unit 52 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS111XA30
-
HEWI Panic bar to EN 1125 PS111XA40
|System 111 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Version for BKS-locks. Handle made of stainless steel, diameter 25 mm with tubular handle made of stainless steel, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 32 mm, width of the transmission unit 52 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS111XA40
-
HEWI Panic bar to EN 1125 PS160XA10
|System 162 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Handle made of stainless steel, diameter 25 mm with tubular handle made of polyamide, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side, conforms to the requirements of DIN 18040. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 27.7 mm, width of the transmission unit 45 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS160XA10
-
HEWI Panic bar to EN 1125 PS160XA20
|System 162 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Handle made of stainless steel, diameter 25 mm with tubular handle made of stainless steel, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 27.7 mm, width of the transmission unit 45 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS160XA20
-
HEWI Panic bar to EN 1125 PS160XA30
|System 162 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Version for BKS-locks. Handle made of stainless steel, diameter 25 mm with tubular handle made of polyamide, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side, conforms to the requirements of DIN 18040. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 32 mm, width of the transmission unit 52 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS160XA30
-
HEWI Panic bar to EN 1125 PS160XA40
|System 162 panic bar for equipping exit doors - approval to EN 1125 only in combination with tested locks - with CE marking. Approved for fire and smoke doors, listing in the national technical approval test certificate of the respective door manufacturer in conjunction with DIN 18273, DIN 4102, DIN 1634, for single leaf or double doorsets in escape routes (inactive or inactive and active leaf) Version for BKS-locks. Handle made of stainless steel, diameter 25 mm with tubular handle made of stainless steel, diameter 30 mm. Handle tube positioned as one-sided handle, therefore clear visualisation of the optimum pressure point on the lock side. The stainless steel tubes are connected by a square bar - telescopic. Low projection depending on the operating angle of the lock follower, but at least in accordance with DIN 1125, grade 2: <= 100 mm. Mounting distance 761 - 860 mm, 861 - 1010 mm, 1011 - 1160 mm, 1161 - 1300 mm, 301 - 1440 mm and 1441 - 1580 mm. Variable mounting distance: shorter bar (fixing centres > 761 mm) at customer request, specify exact measurement. For use on timber and steel doors and metal frame doors, backset from 35 mm (depending on profile) as single or double doorset. Concealed, tamper-resistant screw fixing with threaded screws M5. Gear unit and the thrust bearing with cover, width of the rosette 32 mm, width of the transmission unit 52 mm, no jamming due to splayed surfaces of the gear unit cover on the lock side and positioning of the push-bar on the inside of the gear unit. Surface satin finished Designed and tested for projects, classification to EN 1125 Category of use: Class 3 Durability: Class 7 Door mass: Class 6 Suitability for use on fire and smoke doors: Class B Safety - personal protection: Class 1 Corrosion resistance: Class 3 Security - burglary protection: Class 2 Projection of device: Class 2 Type of device: A Field of door application: Class A Article no.: HEWI PS160XA40
-
UL 2,5 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 2,5-1 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 4 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 4-1 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 6,3 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
UL 10 ULTRIMIS W Ultrasonic Water Meter
|High-quality Ultrimis W ultrasonic water meters: The Ultrimis W is an ultrasonic water meter with many patented design and technological features, such as the proprietary "W-Sonic Technology" ultrasonic measuring method. None of the materials in contact with water used for the construction of this meter contain heavy metals. The standard version of this water meter is fully waterproof. The innovative structure makes our product arguably the lightest and smallest ultrasonic water meter available to our customers. Use: Our ultrasonic water meters measure the flow and volume of water up to a max. temperature of 50°C using a closed-loop system, with the full flow rates up to a max. pressure of 16 bar (PN16). This is important, especially when precision measurement of water consumption and the application of modern communication technologies are required, including NFC and radio reading systems. The water meters feature an e-display (IP68); may be installed in any orientation (H, V, H/V) and do not require the use of U0D0 straight sections, filters or check valves.
-
Energy Monitoring Power Conditioner & Controller 200 - PC-200
|<p>The PC-200 is a professional grade, rack-mountable power conditioner and controller designed to provide 120 Volt AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. Eight switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected, filtered, and monitored. The switched outlets are arranged in four banks of two, three of which are turn-on delay-adjustable when controlled from the front panel power switch. The same three outlet banks are also individually controllable via a control system to enable selective switching of devices, on/off power sequencing, load-shedding, and other custom power control functionality.[1]<br>Built-in RMS voltage and current monitoring enables logging and reporting of the line voltage, current, power, and energy usage at the input. An external temperature sensor is included to keep tabs on heat conditions within the equipment rack or room. Network connectivity allows for setup and operation using a web browser, with extensive custom control and monitoring capabilities enabled through integration with a Crestron control system, the MyCrestron.com residential monitoring service, the Crestron Fusion® Cloud enterprise management service, or an SNMP client.[1,2]<br><br></p><strong>Power Conditioning<br></strong>A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-200 includes the following power conditioning features:<br><ul><li><strong>Surge Protection</strong> &mdash; Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances</li><li><strong>Under/Over Voltage Cutoff</strong> &mdash; Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range, which is adjustable on the PC-200</li><li><strong>Thermal Breaker</strong> &mdash; Disrupts power to all outlets in case of an overload condition</li><li><strong>EMI/RFI Noise Filtering</strong> &mdash; Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality</li><li><strong>Wiring Fault Detection</strong> &mdash; Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [3]</li></ul><p><strong>Four-Stage Adjustable Turn-On Delay</strong><br>The switched outlets on the PC-200’s rear panel are arranged in four banks, with two outlets per bank. When operated by its front panel power switch, the first bank turns on immediately while the other three banks can be configured to turn on in any order according to the delay time set for each bank. Each bank is independently adjustable to provide up to 10 seconds of delay before turning on, ensuring that the connected equipment gets powered up in proper order with sufficient time for each piece to stabilize. This helps to prevent dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up. Delayed turn-on is initiated by turning on the front panel power switch, or by applying power to the main line input following a power outage or through an externally switched circuit.<br><br></p><p><strong>Three Remote-Controllable Switched Outlet Banks</strong><br>When connected to a local area network, three of the four outlet banks on the PC-200’s rear panel can be turned on or off independently using a web browser or control system. The other bank is always on as long as the front panel switch is turned on. This energy-saving feature allows select components to be powered down when not needed. Through integration with a control system, custom functionality can be programmed to enable control from a touch screen, keypad, remote, or mobile device. Sequential power-up and power-down functionality can be enabled through programming of the control system. For systems employing a backup generator or UPS, load-shedding can be performed to shut down unnecessary components during a power outage.[1]<br><br></p><strong>Energy Monitoring<br></strong>By sensing the incoming line voltage and the total device load, the PC-200 facilitates a host of solutions for monitoring, automating, and troubleshooting a system.<br><ul><li>Voltage monitoring allows fluctuations in the power line to be tracked and logged, helping to identify and document problems with the power utility or building wiring.</li><li>Energy monitoring provides the real power consumption (watts), current draw (amps), and energy usage (watt-hours) for all of the connected devices combined.</li><li>By connecting and testing one component at a time, the PC-200 allows power-hungry equipment to be identified and replaced with more efficient equipment.</li><li>High inrush current devices can be identified to assist in optimizing the configuration of power sequencing schemes.</li><li>Overall energy usage can be tracked and logged to identify trends and reform energy-wasting behaviors.</li><li>System usage can be tracked to inform the scheduling of maintenance and future purchasing decisions.</li><li>An alert notification can be sent if there’s a sudden or abnormal drop in current draw, potentially indicating a device has been shut off improperly or disconnected due to theft (effective only when outlets are switched on).</li></ul><p><strong>Ambient Temperature Sensing</strong></p><p>The PC-200 offers a complete equipment protection solution by monitoring the ambient temperature within the equipment cabinet or room to prevent overheating. The included temperature sensor connects to the rear of the PC-200 and features a choice of magnetic or adhesive mounting for easy placement within a typical equipment rack enclosure. The over-temperature cutoff threshold can be set to shut down power to the system if conditions exceed a safe operating temperature. Through a control system, the temperature measurement can be utilized to regulate the operation of cooling fans or air-conditioning equipment to keep equipment running cool.</p><p><strong>Ping Monitoring</strong></p><p>No matter how well a system is designed and programmed, even the finest control system or computer has the potential to lock up and stop responding once in a while. The PC-200 can be configured to detect an unresponsive device by sending it a ping command at regular intervals. If the ping request is not returned after four tries, the outlet bank feeding the monitored device cycles off and on to reboot the device, quickly restoring normal operation without any human intervention.</p><p><strong>Remote Management & Control</strong><br></p><p>The PC-200 integrates neatly into any system or facility. Used alone, it can be set up and managed through a web browser. It can also be configured to send email notifications in case of certain specified events. Integration with the MyCrestron.com residential monitoring service provides a cloud based solution for homeowners to monitor and manage the PC-200 as part of a complete Crestron home automation system. Or, Crestron Fusion Cloud provides an enterprise solution for corporations and universities to manage rooms using the PC-200 throughout a building or campus. Built-in SNMP support enables integration with third-party IT management software, allowing network administrators to manage one or many networked PC-200s in an IT-friendly format. And of course, the PC-200 can be integrated with a Crestron control system via Ethernet or Cresnet® to enable control and monitoring through a touch screen, handheld remote, or mobile device.[1,2]</p><p><strong>Key Features</strong><br></p><ul><li>Rack-mountable power conditioner and controller</li><li>Eight switched rear panel outlets, arranged in banks of two</li><li>Adjustable turn-on delay and remote switching per each of three banks</li><li>One unswitched front panel outlet</li><li>Built-in current sensing and energy monitoring</li><li>Line voltage monitoring</li><li>Professional grade surge protection</li><li>UL® 1449 Type 3 Listed</li><li>Thermal breaker overload protection</li><li>Adjustable over-voltage and under-voltage cutoff</li><li>EMI and RFI noise filtering</li><li>Wiring fault detection [3]</li><li>Ambient temperature sensing and over-temperature cutoff</li><li>Ping monitoring (device lockup detection and reboot)</li><li>Built-in energy usage and event logging</li><li>Front panel main power switch and status indicators</li><li>Easy setup and operation via web browser</li><li>Crestron® control system integration via Ethernet or Cresnet®</li><li>Remote management via MyCrestron.com, Crestron Fusion® Cloud, or SNMP [2]</li><li>Single-space 19 inch rack-mountable</li><li>Rated 15 Amps at 120 Volts AC</li><li>Limited Lifetime Product Warranty</li><li>Limited 5 Year Connected Equipment Protection Warranty</li></ul><p>1. Crestron control system and custom programming sold separately.<br>2. Email notification and direct integration with MyCrestron.com, Crestron Fusion, and SNMP will be enabled through a future firmware update. Alternately, these services can be integrated now through a Crestron control system with custom programming.<br>3. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-200 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-200 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.</p>
-
Energy Monitoring Power Conditioner & Controller 300 - PC-300
|<p>The PC-300 is a professional grade, rack-mountable power conditioner and controller designed to provide 120 Volt AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. Eight individually-switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected, filtered, and monitored. The switched outlets are each turn-on delay-adjustable when controlled from the front panel power switch. The switched outlets are also individually controllable via a control system to enable independent switching of devices, on/off power sequencing, load-shedding, and other custom power control functionality.[1]</p><p>Built-in RMS voltage and current monitoring enables logging and reporting of line voltage fluctuations at the input, as well as current, power, and energy usage at each outlet. An external temperature sensor is included to keep tabs on heat conditions within the equipment rack or room. Network connectivity allows for setup and operation using a web browser, with extensive custom control and monitoring capabilities enabled through integration with a Crestron control system, the MyCrestron.com residential monitoring service, the Crestron Fusion® Cloud enterprise management service, or an SNMP client.[1,2] Setup and operation can also be performed through the LCD front panel.</p><p> </p><strong>Power Conditioning<br></strong>A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-300 includes the following power conditioning features:<br><ul><li><strong>Surge Protection</strong> &mdash; Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances</li><li><strong>Under/Over Voltage Cutoff</strong> &mdash; Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range, which is adjustable on the PC-300</li><li><strong>Thermal Breaker</strong> &mdash; Disrupts power to all outlets in case of an overload condition</li><li><strong>EMI/RFI Noise Filtering</strong> &mdash; Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality</li><li><strong>Wiring Fault Detection</strong> &mdash; Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [3]</li></ul> <p><strong>Eight-Stage Adjustable Turn-On Delay</strong><br>When operated by its front panel power switch, the PC-300 allows each of its rear panel outlets to turn on in any order according to the delay time set for each outlet. Each outlet is individually adjustable to provide up to 10 seconds of delay before turning on, ensuring that the connected equipment gets powered up in proper order with sufficient time for each piece to stabilize. This helps to prevent dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up. Delayed turn-on is initiated by turning on the front panel power switch, or by applying power to the main line input following a power outage or through an externally switched circuit.<br><br></p><p><strong>Eight Remote-Controllable Switched Outlets</strong><br>Any of the PC-300’s eight rear panel outlets can be turned on or off individually through the front panel LCD screen or over the network using a web browser or control system. This energy-saving feature allows select components to be powered down when not needed. Through integration with a control system, custom functionality can be programmed to enable control from a touch screen, keypad, remote, or mobile device. Sequential power-up and power-down functionality can be enabled through programming of the control system, with select outlets designated as always on. For systems employing a backup generator or UPS, load-shedding can be performed to shut down unnecessary components during a power outage.[1]</p><p> </p><strong>Energy Monitoring</strong><br>By sensing the incoming line voltage and individual device loads, the PC-300 facilitates a host of solutions for monitoring, automating, and troubleshooting a system.<br><ul><li>Voltage monitoring allows fluctuations in the power line to be tracked and logged, helping to identify and document problems with the power utility or building wiring.</li><li>Energy monitoring per outlet provides the real power consumption (watts), current draw (amps), and energy usage (watt-hours) for each connected device.</li><li>Allows power-hungry equipment to be identified and replaced with more efficient equipment.</li><li>High inrush current devices can be identified to assist in optimizing the configuration of power sequencing schemes.</li><li>Overall energy usage can be tracked and logged to identify trends and reform energy-wasting behaviors.</li><li>Individual device usage can be tracked to inform the scheduling of maintenance and future purchasing decisions.</li><li>The power state of an IR controlled device can often be determined by sensing its AC current draw, ensuring it’s on when it should be on.</li><li>An alert notification can be sent if there’s a sudden or abnormal drop in current draw, potentially indicating a device has been shut off improperly or disconnected due to theft (effective only when outlets are switched on).</li></ul><p> </p><p><strong>Ambient Temperature Sensing</strong><br>The PC-300 offers a complete equipment protection solution by monitoring the ambient temperature within the equipment cabinet or room to prevent overheating. The included temperature sensor connects to the rear of the PC-300 and features a choice of magnetic or adhesive mounting for easy placement within a typical equipment rack enclosure. The over-temperature cutoff threshold can be set to shut down power to the system if conditions exceed a safe operating temperature. Through a control system, the temperature measurement can be utilized to regulate the operation of cooling fans or air-conditioning equipment to keep equipment running cool.</p> <p><strong>Ping Monitoring</strong><br>No matter how well a system is designed and programmed, even the finest control system or computer has the potential to lock up and stop responding once in a while. The PC-300 can be configured to detect an unresponsive device by sending it a ping command at regular intervals. If the ping request is not returned after four tries, the outlet feeding the monitored device cycles off and on to reboot the device, quickly restoring normal operation without any human intervention.</p> <p><strong>Built-In Logging</strong><br>Events such as power surges, over/under voltage conditions, over-temperature conditions, ping failures, outlet switching activity, and sudden changes in current draw (indicative of a device being improperly shut off or disconnected) can all be logged as they occur to document the time and cause of problems and to track device usage. All sensor readings are logged at a configurable interval as short as five seconds providing a minimum of one week’s worth of data. Logs can be retrieved periodically to record a detailed history of events and energy usage over time.</p> <strong>UL® 1449 Certified</strong><br>The PC-300 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).<br>&nbsp;&nbsp;<br><strong>Key Features</strong><br><ul><li>Rack-mountable power conditioner and controller</li><li>Eight individual-switched rear panel outlets</li><li>Adjustable turn-on delay and local/remote switching per outlet</li><li>One unswitched front panel outlet</li><li>Built-in current sensing and energy monitoring per outlet</li><li>Line voltage monitoring</li><li>Professional grade surge protection</li><li>UL® 1449 Type 3 Listed</li><li>Thermal breaker overload protection</li><li>Adjustable over-voltage and under-voltage cutoff</li><li>EMI and RFI noise filtering</li><li>Wiring fault detection [3]</li><li>Ambient temperature sensing and over-temperature cutoff</li><li>Ping monitoring (device lockup detection and reboot)</li><li>Built-in energy usage and event logging</li><li>Front panel main power switch, status indicators, and color LCD</li><li>Easy setup and operation via front panel or web browser</li><li>Crestron® control system integration via Ethernet or Cresnet®</li><li>Remote management via MyCrestron.com, Crestron Fusion® Cloud, or SNMP [2]</li><li>Single-space 19 inch rack-mountable</li><li>Rated 15 Amps at 120 Volts AC</li><li>Limited Lifetime Product Warranty</li><li>Limited 5 Year Connected Equipment Protection Warranty</li></ul> <p>1. Crestron control system and custom programming sold separately.<br>2. Email notification and direct integration with MyCrestron.com, Crestron Fusion, and SNMP will be enabled through a future firmware update. Alternately, these services can be integrated now through a Crestron control system with custom programming.<br>3. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-300 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-300 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.</p>
