-
Tie Fighter Exercise
Rafał Ślęk | 1368440441Tie Fighter made on start PLN file as it was prepared by Graphisoft. 2D for Object wasn't cleaned as i is simple test how hard it is build such Morphs from scratch. :-)
-
G1026 - Exercise Apparatus, Weight Training, Multi-Station
|Multi-station weight training apparatus for physical development and rehabilitation. Unit features a variety of benches, pull bars, supports and seats grouped around a central frame containing one or more weight stacks. Each station is designed to exercise specific muscle groups. A person can perform an extensive weight training routine by moving around the apparatus from station to station. More than one person can use the apparatus simultaneously by training at different stations. The number and types of exercises available depend on the specific model of equipment chosen. Greater system weight capacities for high level athletic competition training are available on some models. The room ceiling may have to be raised to accommodate this equipment. The database specifications refer to a higher end system with a large number of training stations and a standard weight set.
-
M8185 - System, Stress Exercise, w/Treadmill
|Stress exercise system with treadmill and respiratory/metabolic assessment. The system includes an ECG amplifier, chart recorder, display, console, treadmill and modules for respiratory/metabolic assessment. Used to determine patient's functional capacity, predict and diagnose cardiopulmonary and vascular diseases and for rehabilitation of patients recovering from leg injuries or other type of illness. Some vendors require a NEMA 5-20R non-locking receptacle for their treadmills.
-
M7905 - Oximeter, Pulse
|Pulse oximeter for continuous surveillance of patient pulse and oxygen saturation rates. Instrument features LED display, audio and visual alarms, automatic calibration and battery operation in case of power failure. Other applications include sleep studies, exercise testing and monitoring certain patients in the home (e.g. infants or patients requiring respiratory therapy).
-
M8145 - Exerciser, Staircase, Convertible
|Convertible exercise staircase. Staircase is sturdily built in two sections permitting a corner type or straight type arrangement. It consists of steps 30-36" wide and a square platform. It includes handrails to accommodate both children and adults. Both steps and platform are covered with non-slip tread.
-
K2 Seat - ergonomic pouf
|In the beginning K2 Seat might seem like an advanced balance exercise, but as soon as you get your grip on it the comfort is incomparable to any other pouf. Besides strengthening your balance and posture the K2 Seat creates an exceptional experience. In meetings the K2 Seat opens up for playful ideas and a dynamic dialog. But the pouf works at the dining table, at your desk or in the living room as well. The ergonomic bottom of the pouf is made of solid cork with an integrated tilt that makes sure that the K2 Seat can gently move around on the floor without making any noise or damage. The optional hook, which is fastened on the bottom under the upholstery, makes it possible to easily move the pouf around if you wish to do so.
-
Kebne 1, outdoor gym
|Kebne is not just another outdoor gym, but a centre for activity and exercise for the whole community. Designed with outdoor fitness in mind, Kebne is a system of three-dimensional frames for low-impact resistance training, overall body conditioning, stretching, flexing, fun and play. The design is comprised of five ergonomic units that provide stations for exercise in urban parks or in landscapes outside the city centre. Easy-to-understand diagrams are attached to the frames to show how the system can be used. Design: Kauppi & Kauppi
-
Kebne 2, outdoor gym
|Kebne is not just another outdoor gym, but a centre for activity and exercise for the whole community. Designed with outdoor fitness in mind, Kebne is a system of three-dimensional frames for low-impact resistance training, overall body conditioning, stretching, flexing, fun and play. The design is comprised of five ergonomic units that provide stations for exercise in urban parks or in landscapes outside the city centre. Easy-to-understand diagrams are attached to the frames to show how the system can be used. Design: Kauppi & Kauppi
-
Kebne 3, outdoor gym
|Kebne is not just another outdoor gym, but a centre for activity and exercise for the whole community. Designed with outdoor fitness in mind, Kebne is a system of three-dimensional frames for low-impact resistance training, overall body conditioning, stretching, flexing, fun and play. The design is comprised of five ergonomic units that provide stations for exercise in urban parks or in landscapes outside the city centre. Easy-to-understand diagrams are attached to the frames to show how the system can be used. Design: Kauppi & Kauppi
-
Kebne 4, outdoor gym
|Kebne is not just another outdoor gym, but a centre for activity and exercise for the whole community. Designed with outdoor fitness in mind, Kebne is a system of three-dimensional frames for low-impact resistance training, overall body conditioning, stretching, flexing, fun and play. The design is comprised of five ergonomic units that provide stations for exercise in urban parks or in landscapes outside the city centre. Easy-to-understand diagrams are attached to the frames to show how the system can be used. Design: Kauppi & Kauppi
-
Kebne 5, outdoor gym
|Kebne is not just another outdoor gym, but a centre for activity and exercise for the whole community. Designed with outdoor fitness in mind, Kebne is a system of three-dimensional frames for low-impact resistance training, overall body conditioning, stretching, flexing, fun and play. The design is comprised of five ergonomic units that provide stations for exercise in urban parks or in landscapes outside the city centre. Easy-to-understand diagrams are attached to the frames to show how the system can be used. Design: Kauppi & Kauppi
-
Power Conditioner 100 - PC-100
|<p>The PC-100 is a professional grade, rack-mountable power conditioner designed to provide 120 Volt AC power distribution, switching, surge protection, and noise filtering for Crestron® control systems, AV systems, computers, and other equipment. Eight switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected and filtered. The switched outlets are arranged in four banks of two, two of which are turn-on delayed to prevent dangerous transients during power-up.<br><br></p><strong>Power Conditioning<br></strong>A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-100 includes the following power conditioning features:<br><ul><li><strong>Surge Protection</strong> &mdash; Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances</li><li><strong>Under/Over Voltage Cutoff</strong> &mdash; Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range</li><li><strong>Thermal Breaker</strong> &mdash; Disrupts power to all outlets in case of an overload condition</li><li><strong>EMI/RFI Noise Filtering</strong> &mdash; Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality</li><li><strong>Wiring Fault Detection</strong> &mdash; Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [1]</li></ul><strong>Three-Stage Sequential Turn-On Delay</strong><br>The switched outlets on the PC-100’s rear panel are arranged in four banks, with two outlets per bank. When the front panel switch is turned on, or when power is applied to the main line input following a power outage or through an externally switched circuit, the first two banks of outlets turn on immediately, the third bank turns on following a one second delay, and the fourth bank turns on following a two second delay. This ensures that the connected equipment gets powered up in proper order, preventing dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up.<br><p><br></p><p><strong>Protection Status Output</strong></p>A contact closure output is included to provide notification to a control system or other equipment if the internal surge protection circuit is compromised due to an extreme transient voltage surge. In the unlikely event of such a condition, the PROTECTION output presents a low-voltage contact closure signal and all power to the rear panel outlets is switched off. Protection status is also indicated via LEDs on the front panel.<br><p><br></p><p><strong>UL® 1449 Certified</strong></p><p>The PC-100 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).<br></p><p></p><p>&nbsp;&nbsp;</p><p><strong>Key Features</strong></p><ul><li>Rack-mountable power conditioner</li><li>Eight switched rear panel outlets</li><li>Three-stage sequential turn-on delay</li><li>One unswitched front panel outlet</li><li>Professional grade surge protection</li><li>UL® 1449 Type 3 Listed</li><li>Thermal breaker overload protection</li><li>Over-voltage and under-voltage cutoff</li><li>EMI and RFI noise filtering</li><li>Wiring fault detection [1]</li><li>Front panel main power switch and status indicators</li><li>Protection status contact closure output</li><li>Single-space 19 inch rack-mountable</li><li>Rated 15 Amps at 120 Volts AC</li><li>Limited Lifetime Product Warranty</li><li>Limited 5 Year Connected Equipment Protection Warranty</li></ul><p>1. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-100 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-100 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.</p>
-
Energy Monitoring Power Conditioner & Controller 200 - PC-200
|<p>The PC-200 is a professional grade, rack-mountable power conditioner and controller designed to provide 120 Volt AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. Eight switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected, filtered, and monitored. The switched outlets are arranged in four banks of two, three of which are turn-on delay-adjustable when controlled from the front panel power switch. The same three outlet banks are also individually controllable via a control system to enable selective switching of devices, on/off power sequencing, load-shedding, and other custom power control functionality.[1]<br>Built-in RMS voltage and current monitoring enables logging and reporting of the line voltage, current, power, and energy usage at the input. An external temperature sensor is included to keep tabs on heat conditions within the equipment rack or room. Network connectivity allows for setup and operation using a web browser, with extensive custom control and monitoring capabilities enabled through integration with a Crestron control system, the MyCrestron.com residential monitoring service, the Crestron Fusion® Cloud enterprise management service, or an SNMP client.[1,2]<br><br></p><strong>Power Conditioning<br></strong>A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-200 includes the following power conditioning features:<br><ul><li><strong>Surge Protection</strong> &mdash; Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances</li><li><strong>Under/Over Voltage Cutoff</strong> &mdash; Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range, which is adjustable on the PC-200</li><li><strong>Thermal Breaker</strong> &mdash; Disrupts power to all outlets in case of an overload condition</li><li><strong>EMI/RFI Noise Filtering</strong> &mdash; Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality</li><li><strong>Wiring Fault Detection</strong> &mdash; Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [3]</li></ul><p><strong>Four-Stage Adjustable Turn-On Delay</strong><br>The switched outlets on the PC-200’s rear panel are arranged in four banks, with two outlets per bank. When operated by its front panel power switch, the first bank turns on immediately while the other three banks can be configured to turn on in any order according to the delay time set for each bank. Each bank is independently adjustable to provide up to 10 seconds of delay before turning on, ensuring that the connected equipment gets powered up in proper order with sufficient time for each piece to stabilize. This helps to prevent dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up. Delayed turn-on is initiated by turning on the front panel power switch, or by applying power to the main line input following a power outage or through an externally switched circuit.<br><br></p><p><strong>Three Remote-Controllable Switched Outlet Banks</strong><br>When connected to a local area network, three of the four outlet banks on the PC-200’s rear panel can be turned on or off independently using a web browser or control system. The other bank is always on as long as the front panel switch is turned on. This energy-saving feature allows select components to be powered down when not needed. Through integration with a control system, custom functionality can be programmed to enable control from a touch screen, keypad, remote, or mobile device. Sequential power-up and power-down functionality can be enabled through programming of the control system. For systems employing a backup generator or UPS, load-shedding can be performed to shut down unnecessary components during a power outage.[1]<br><br></p><strong>Energy Monitoring<br></strong>By sensing the incoming line voltage and the total device load, the PC-200 facilitates a host of solutions for monitoring, automating, and troubleshooting a system.<br><ul><li>Voltage monitoring allows fluctuations in the power line to be tracked and logged, helping to identify and document problems with the power utility or building wiring.</li><li>Energy monitoring provides the real power consumption (watts), current draw (amps), and energy usage (watt-hours) for all of the connected devices combined.</li><li>By connecting and testing one component at a time, the PC-200 allows power-hungry equipment to be identified and replaced with more efficient equipment.</li><li>High inrush current devices can be identified to assist in optimizing the configuration of power sequencing schemes.</li><li>Overall energy usage can be tracked and logged to identify trends and reform energy-wasting behaviors.</li><li>System usage can be tracked to inform the scheduling of maintenance and future purchasing decisions.</li><li>An alert notification can be sent if there’s a sudden or abnormal drop in current draw, potentially indicating a device has been shut off improperly or disconnected due to theft (effective only when outlets are switched on).</li></ul><p><strong>Ambient Temperature Sensing</strong></p><p>The PC-200 offers a complete equipment protection solution by monitoring the ambient temperature within the equipment cabinet or room to prevent overheating. The included temperature sensor connects to the rear of the PC-200 and features a choice of magnetic or adhesive mounting for easy placement within a typical equipment rack enclosure. The over-temperature cutoff threshold can be set to shut down power to the system if conditions exceed a safe operating temperature. Through a control system, the temperature measurement can be utilized to regulate the operation of cooling fans or air-conditioning equipment to keep equipment running cool.</p><p><strong>Ping Monitoring</strong></p><p>No matter how well a system is designed and programmed, even the finest control system or computer has the potential to lock up and stop responding once in a while. The PC-200 can be configured to detect an unresponsive device by sending it a ping command at regular intervals. If the ping request is not returned after four tries, the outlet bank feeding the monitored device cycles off and on to reboot the device, quickly restoring normal operation without any human intervention.</p><p><strong>Remote Management & Control</strong><br></p><p>The PC-200 integrates neatly into any system or facility. Used alone, it can be set up and managed through a web browser. It can also be configured to send email notifications in case of certain specified events. Integration with the MyCrestron.com residential monitoring service provides a cloud based solution for homeowners to monitor and manage the PC-200 as part of a complete Crestron home automation system. Or, Crestron Fusion Cloud provides an enterprise solution for corporations and universities to manage rooms using the PC-200 throughout a building or campus. Built-in SNMP support enables integration with third-party IT management software, allowing network administrators to manage one or many networked PC-200s in an IT-friendly format. And of course, the PC-200 can be integrated with a Crestron control system via Ethernet or Cresnet® to enable control and monitoring through a touch screen, handheld remote, or mobile device.[1,2]</p><p><strong>Key Features</strong><br></p><ul><li>Rack-mountable power conditioner and controller</li><li>Eight switched rear panel outlets, arranged in banks of two</li><li>Adjustable turn-on delay and remote switching per each of three banks</li><li>One unswitched front panel outlet</li><li>Built-in current sensing and energy monitoring</li><li>Line voltage monitoring</li><li>Professional grade surge protection</li><li>UL® 1449 Type 3 Listed</li><li>Thermal breaker overload protection</li><li>Adjustable over-voltage and under-voltage cutoff</li><li>EMI and RFI noise filtering</li><li>Wiring fault detection [3]</li><li>Ambient temperature sensing and over-temperature cutoff</li><li>Ping monitoring (device lockup detection and reboot)</li><li>Built-in energy usage and event logging</li><li>Front panel main power switch and status indicators</li><li>Easy setup and operation via web browser</li><li>Crestron® control system integration via Ethernet or Cresnet®</li><li>Remote management via MyCrestron.com, Crestron Fusion® Cloud, or SNMP [2]</li><li>Single-space 19 inch rack-mountable</li><li>Rated 15 Amps at 120 Volts AC</li><li>Limited Lifetime Product Warranty</li><li>Limited 5 Year Connected Equipment Protection Warranty</li></ul><p>1. Crestron control system and custom programming sold separately.<br>2. Email notification and direct integration with MyCrestron.com, Crestron Fusion, and SNMP will be enabled through a future firmware update. Alternately, these services can be integrated now through a Crestron control system with custom programming.<br>3. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-200 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-200 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.</p>
-
Energy Monitoring Power Conditioner & Controller 300 - PC-300
|<p>The PC-300 is a professional grade, rack-mountable power conditioner and controller designed to provide 120 Volt AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. Eight individually-switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected, filtered, and monitored. The switched outlets are each turn-on delay-adjustable when controlled from the front panel power switch. The switched outlets are also individually controllable via a control system to enable independent switching of devices, on/off power sequencing, load-shedding, and other custom power control functionality.[1]</p><p>Built-in RMS voltage and current monitoring enables logging and reporting of line voltage fluctuations at the input, as well as current, power, and energy usage at each outlet. An external temperature sensor is included to keep tabs on heat conditions within the equipment rack or room. Network connectivity allows for setup and operation using a web browser, with extensive custom control and monitoring capabilities enabled through integration with a Crestron control system, the MyCrestron.com residential monitoring service, the Crestron Fusion® Cloud enterprise management service, or an SNMP client.[1,2] Setup and operation can also be performed through the LCD front panel.</p><p> </p><strong>Power Conditioning<br></strong>A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-300 includes the following power conditioning features:<br><ul><li><strong>Surge Protection</strong> &mdash; Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances</li><li><strong>Under/Over Voltage Cutoff</strong> &mdash; Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range, which is adjustable on the PC-300</li><li><strong>Thermal Breaker</strong> &mdash; Disrupts power to all outlets in case of an overload condition</li><li><strong>EMI/RFI Noise Filtering</strong> &mdash; Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality</li><li><strong>Wiring Fault Detection</strong> &mdash; Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [3]</li></ul> <p><strong>Eight-Stage Adjustable Turn-On Delay</strong><br>When operated by its front panel power switch, the PC-300 allows each of its rear panel outlets to turn on in any order according to the delay time set for each outlet. Each outlet is individually adjustable to provide up to 10 seconds of delay before turning on, ensuring that the connected equipment gets powered up in proper order with sufficient time for each piece to stabilize. This helps to prevent dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up. Delayed turn-on is initiated by turning on the front panel power switch, or by applying power to the main line input following a power outage or through an externally switched circuit.<br><br></p><p><strong>Eight Remote-Controllable Switched Outlets</strong><br>Any of the PC-300’s eight rear panel outlets can be turned on or off individually through the front panel LCD screen or over the network using a web browser or control system. This energy-saving feature allows select components to be powered down when not needed. Through integration with a control system, custom functionality can be programmed to enable control from a touch screen, keypad, remote, or mobile device. Sequential power-up and power-down functionality can be enabled through programming of the control system, with select outlets designated as always on. For systems employing a backup generator or UPS, load-shedding can be performed to shut down unnecessary components during a power outage.[1]</p><p> </p><strong>Energy Monitoring</strong><br>By sensing the incoming line voltage and individual device loads, the PC-300 facilitates a host of solutions for monitoring, automating, and troubleshooting a system.<br><ul><li>Voltage monitoring allows fluctuations in the power line to be tracked and logged, helping to identify and document problems with the power utility or building wiring.</li><li>Energy monitoring per outlet provides the real power consumption (watts), current draw (amps), and energy usage (watt-hours) for each connected device.</li><li>Allows power-hungry equipment to be identified and replaced with more efficient equipment.</li><li>High inrush current devices can be identified to assist in optimizing the configuration of power sequencing schemes.</li><li>Overall energy usage can be tracked and logged to identify trends and reform energy-wasting behaviors.</li><li>Individual device usage can be tracked to inform the scheduling of maintenance and future purchasing decisions.</li><li>The power state of an IR controlled device can often be determined by sensing its AC current draw, ensuring it’s on when it should be on.</li><li>An alert notification can be sent if there’s a sudden or abnormal drop in current draw, potentially indicating a device has been shut off improperly or disconnected due to theft (effective only when outlets are switched on).</li></ul><p> </p><p><strong>Ambient Temperature Sensing</strong><br>The PC-300 offers a complete equipment protection solution by monitoring the ambient temperature within the equipment cabinet or room to prevent overheating. The included temperature sensor connects to the rear of the PC-300 and features a choice of magnetic or adhesive mounting for easy placement within a typical equipment rack enclosure. The over-temperature cutoff threshold can be set to shut down power to the system if conditions exceed a safe operating temperature. Through a control system, the temperature measurement can be utilized to regulate the operation of cooling fans or air-conditioning equipment to keep equipment running cool.</p> <p><strong>Ping Monitoring</strong><br>No matter how well a system is designed and programmed, even the finest control system or computer has the potential to lock up and stop responding once in a while. The PC-300 can be configured to detect an unresponsive device by sending it a ping command at regular intervals. If the ping request is not returned after four tries, the outlet feeding the monitored device cycles off and on to reboot the device, quickly restoring normal operation without any human intervention.</p> <p><strong>Built-In Logging</strong><br>Events such as power surges, over/under voltage conditions, over-temperature conditions, ping failures, outlet switching activity, and sudden changes in current draw (indicative of a device being improperly shut off or disconnected) can all be logged as they occur to document the time and cause of problems and to track device usage. All sensor readings are logged at a configurable interval as short as five seconds providing a minimum of one week’s worth of data. Logs can be retrieved periodically to record a detailed history of events and energy usage over time.</p> <strong>UL® 1449 Certified</strong><br>The PC-300 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).<br>&nbsp;&nbsp;<br><strong>Key Features</strong><br><ul><li>Rack-mountable power conditioner and controller</li><li>Eight individual-switched rear panel outlets</li><li>Adjustable turn-on delay and local/remote switching per outlet</li><li>One unswitched front panel outlet</li><li>Built-in current sensing and energy monitoring per outlet</li><li>Line voltage monitoring</li><li>Professional grade surge protection</li><li>UL® 1449 Type 3 Listed</li><li>Thermal breaker overload protection</li><li>Adjustable over-voltage and under-voltage cutoff</li><li>EMI and RFI noise filtering</li><li>Wiring fault detection [3]</li><li>Ambient temperature sensing and over-temperature cutoff</li><li>Ping monitoring (device lockup detection and reboot)</li><li>Built-in energy usage and event logging</li><li>Front panel main power switch, status indicators, and color LCD</li><li>Easy setup and operation via front panel or web browser</li><li>Crestron® control system integration via Ethernet or Cresnet®</li><li>Remote management via MyCrestron.com, Crestron Fusion® Cloud, or SNMP [2]</li><li>Single-space 19 inch rack-mountable</li><li>Rated 15 Amps at 120 Volts AC</li><li>Limited Lifetime Product Warranty</li><li>Limited 5 Year Connected Equipment Protection Warranty</li></ul> <p>1. Crestron control system and custom programming sold separately.<br>2. Email notification and direct integration with MyCrestron.com, Crestron Fusion, and SNMP will be enabled through a future firmware update. Alternately, these services can be integrated now through a Crestron control system with custom programming.<br>3. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-300 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-300 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.</p>