-
Commercial Bath Stall 16
GRAPHISOFT SE | 1343649851Commercial bath stall(s) in series with optional fixture.
-
Partition Panel 16
GRAPHISOFT SE | 1343649851Optional number of partition panels.
-
Commercial Bath Stall 17
GRAPHISOFT SE | 1371557723Commercial bath stall(s) in series with optional fixture.
-
Partition Panel 17
GRAPHISOFT SE | 1371557723Optional number of partition panels.
-
M5562 - Tester, Visual Acuity, Video/Microprocessor Based
|Visual acuity tester using video (television monitor) and microprocessor technology. This equipment replaces the projector chart and projector in an eye examination lane. Wall bracing is required for mounting the unit directly to the wall without support from below. An optional floor stand can also be used. The unit requires an electrical outlet on the far end wall of the examination lane. This differs from standard eye examination room configurations which normally do not have electrical outlets in that wall. Other options include binocular vision and contrast sensitivity testing.
-
JENDY JOSS PREASSEMBLED Structural Floor
|High thermo-acoustic performance structural floor or roof with Jendy JOSS® system with metal frames, upper covering OSB panels and insulation in rock wool, for a total thickness of 237mm. The structure consists of a frame of galvanized steel, 1.5 mm thick section 50-200-50mm places to 400mm wheelbase; thickness, pitch and height of the profiles as resulting from specific structural calculations. The profiles are secured with vertical warping brackets or inserted within the 40-200-40mm section guides. The top surface of the floor will be covered with a double layer of OSB 3 sheets, normate for static functions and the bracing of the horizontal plane, 12mm thick, screwed to the metal with screws VT4.2*32 galvanized and drilling, crossed and with staggered joints cutlery. The floor lower side will instead be coated with a plasterboard plate of 13mm thickness and 2800-3000x1200mm size screwed to the steel structure with suitable self-threading screws fosfate VT3.5*25. The plasterboard will be finished as a rule with plastering of gypsum-based joint with interposed retina or microperforated tape, plastering of the head of the screws, angles, etc ... In the gap will be inserted one of high density rock wool of 160mm thick 70 kg/m³ with acoustic insulation function. In case of roof will be placed on the upper side a further insulating layer to achieve the desired thermal values and suitable waterproofing of the surface; if it’s an intermediate floor it must be realized the screed plant, possibly dry, with traditional subflooring pad and subsequent paving as usual. Including static design of the floor, exclude the reviewing of the existing part. Vacuum computation for full under 5mq.
-
DE Ytong ThermStrong Monolithic Wall PP4-0,50 U=0,26 W/(m²K) d=384 mm
|The Ytong ThermStrong block is suitable for all load bearing and bracing walls. The low dimensional tolerance and the tongue and groove profiling enable rapid processing in the thin-bed method with a joint thickness of 1 mm. The result is a high-quality and homogeneous masonry with excellent thermal insulation. Due to the low weight, aerated concrete blocks are also suitable for internal walls to be retrofitted as well as for reconstruction and renovation measures. The ecological and non-combustible material also makes the construction materials extremely safe and allows their safe use. Advantages: - thermal conductivity λ = 0.10 W/(mK) - Homogeneous, monolithic - without additional insulation - Provides healthy, balanced room climate - Very high fire protection level: F90-A from 7.5 cm - Economical and stable in value - Ergonomic processing
-
DE Ytong ThermStrong Monolithic Wall PP4-0,50 U=0,24 W/(m²K) d=419 mm
|The Ytong ThermStrong block is suitable for all load bearing and bracing walls. The low dimensional tolerance and the tongue and groove profiling enable rapid processing in the thin-bed method with a joint thickness of 1 mm. The result is a high-quality and homogeneous masonry with excellent thermal insulation. Due to the low weight, aerated concrete blocks are also suitable for internal walls to be retrofitted as well as for reconstruction and renovation measures. The ecological and non-combustible material also makes the construction materials extremely safe and allows their safe use. Advantages: - thermal conductivity λ = 0.10 W/(mK) - Homogeneous, monolithic - without additional insulation - Provides healthy, balanced room climate - Very high fire protection level: F90-A from 7.5 cm - Economical and stable in value - Ergonomic processing
-
DE Ytong ThermStrong Monolithic Wall PP4-0,50 U=0,22 W/(m²K) d=444 mm
|The Ytong ThermStrong block is suitable for all load bearing and bracing walls. The low dimensional tolerance and the tongue and groove profiling enable rapid processing in the thin-bed method with a joint thickness of 1 mm. The result is a high-quality and homogeneous masonry with excellent thermal insulation. Due to the low weight, aerated concrete blocks are also suitable for internal walls to be retrofitted as well as for reconstruction and renovation measures. The ecological and non-combustible material also makes the construction materials extremely safe and allows their safe use. Advantages: - thermal conductivity λ = 0.10 W/(mK) - Homogeneous, monolithic - without additional insulation - Provides healthy, balanced room climate - Very high fire protection level: F90-A from 7.5 cm - Economical and stable in value - Ergonomic processing