Pompa Air Jet Pump
Harbayu Budhi | 1618849608Pompa Air Jet Pump Sample BIM Object
-
Surface Viewer 23 USA
Ransom Ratcliff | 1582242666Object for displaying a sample of each surface in an ArchiCAD model, and its index number. Shows where there are gaps in the surface index sequence. (Turn off Spheres and 3D text for faster speed.)
-
EQUITONE [natura]
|EQUITONE [natura] is a through coloured façade material. Every EQUITONE panel is unique, displaying the raw texture of the fibre cement base material. The material comes in a maximum panel size of 1,25 x 3m (4´x 10´) and can be transformed in any size or shape in the workshop or on-site. Furthermore, the material can be perforated or printed. Visible and invisible fixing methods include riveting, screwing and bonding on metal or wood supporting frames. No matter what design options you explore, the through-coloured nature of EQUITONE assures crisp, monolithic details. Request a sample at www.equitone.com [LIST] NOTE: Revit installer only available for Revit version 2013 and 2014 [/LIST]
-
L1025 - Analyzer, Chemistry, Drug Screening
|Drug screening analyzer. It is a random access chemistry analyzer system. The system's capabilities/components include 23 test channels. Over 600 tests per hour; it accepts sample volumes from 2ml to 20mL, fluorescence/light scatter. Used for measuring electrolytes, routine chemistries, special proteins, therapeutic drug monitoring, EIA and fluorescence immunoassay applications.
-
L1080 - Analyzer, Chemistry, Multichannel
|Laboratory chemistry analyzer. The unit is capable of at least 23 chemistries including electrolytes by ISE (ion-selective electrode). The analyzer can perform any combination of tests, panels or stats on a given sample. The unit has automatic QC and maintenance functions. The instrument is programmable for as many as 400 patient samples.
-
L1105 - Co-Oximeter
|Co-oximeter analyzer. The unit calculates hemoglobin/oxygenation concentrations. The analyzer characteristics/components include a sample readout in no longer than 45 seconds, dual beam optics and a hollow cathode lamp. It is used to calculate oxygen content, capacity, and measured saturation and correlates closely with reference methods.
-
L1180 - Dilutor
|Pipetter/Diluter. It has a sample volume of 20 micro liters and a diluent volume of 5 ml and is compatible with most caustic lab solutions such as HCL, H2SO4 glacial acetic acid, cholesterol reagent, total lipid reagent and a vast number of other corrosives. Each instrument is precisely calibrated to assure dilution accuracy and reproducibility with in 1%. The system also has a factory preset volume ration. The cycle light indicates when units are ready to sample or the dispense hand has a reagent draw-back feature that prevents sample reagent mixing inside the pipette after the dispensing cycle. This is a precise automatic instrument for sampling and dispensing. Used for hemoglobin determinations, and other required dilutions.
-
L1185 - Analyzer, Glucose
|Discrete glucose analyzer. Characteristics include sample volume of 10 microliters, measurement principle of the oxygen rate method, throughput of 67 samples per hour and a glucose value displayed in mg/dl. This is a self contained system with automatic fill and drain cycles. Used for glucose analysis of serum plasma or saliva samples
-
L1931 - Analyzer, Blood Gas
|Blood/gas analyzer. The unit measures for pH, PO2, and PCO2 using a standard sample of 90 microliters or greater. A measurement range of 6.4 to 8.0 for pH, 8 to 200mmHg for PCO2 and 0 to 800 mmHg for PO2 is accommodated by the unit. Used in laboratories to measure blood gas parameters of patient samples. System to provide for the measurement of: pH, pCO2, pO2, BP, tHb, NA+, K+, and CL-, or CA++. Calculated values to include: tCO2, O2 Saturation, CT, HCO3 (actual and standardized), BE (vv and vt) and Hct.
-
L2600 - Counter, Cell, Auto
|Automatic blood cell counter. The counter has a built-in monitoring system. It can perform a test in 13 seconds using a 100 microliter sample and give the results of 3 to 5 parameters of WBC, RBC, Hgb, Hct, and MCV. It has programs that include control data, calibration settings and tests and it has a temperature compensation circuit. Used for hematology analysis.
-
L2660 - Microbiological Identification System
|Microbiological identification system. The systems basic principles of operation consists of: photometry, fluorescence, radiometry, infrared spectrophotometry, and video image analysis, together with a MPLS (multiple-parameter light scattering technique) and a continuous flow-through detection system. It consists of an auto-prep station, auto filter, incubator, detector/reader, waste reservoir, and computer sample throughput of over 200/day. Designed to detect presence of micro organisms in body fluids, test susceptibility of micro organisms to anti microbial agents, and/or determine the minimum inhibitory concentrations of antibiotics in order to identify pathogens.
-
L9840 - Counter, Gamma, RIA, Manual
|Gamma counter. Unit can be either a single well or a multi-well system that requires manual sample changing. It includes a NAl crystal detector. Uses RIA techniques to measure trace quantities of gamma radiation in substances such as hormones, drugs, enzymes, viruses, antibodies, tumor markers and receptors that are found in serum, urine and other body fluids.