-
Hood VB2 60x50
Graphisoft NO GS | 1377175500 -
Hood VB2 80x50
Graphisoft NO GS | 1377175500 -
Hood VB3 60x50 - 12
Graphisoft NO GS | 1377175500 -
Hood VB3 60x50 - 9
Graphisoft NO GS | 1377175500 -
Hood VB3 80x50 - 12
Graphisoft NO GS | 1377175500 -
Hood VB3 80x50 - 15
Graphisoft NO GS | 1377175500 -
Hood VB4 80x50
Graphisoft NO GS | 1377175500 -
Built-in Hood 16
GRAPHISOFT SE | 1343649851Different types of hood that can be built under or inside a cabinet.
-
Hood 16
GRAPHISOFT SE | 1343649851Different types of kitchen hood.
-
Built-in Hood 17
GRAPHISOFT SE | 1371557723Different types of hood that can be built under or inside a cabinet.
-
Hood 17
GRAPHISOFT SE | 1371557723Different types of kitchen hood.
-
L2200 - Hood, Fume, Floor Standing
|Floor standing fume hood. The unit presented is 4 Ft but is available in other sizes. It will include a fluorescent light fixture, blower switch with pilot light, at least one duplex receptacle, a cup sink and shall be acid resistant. The minimum average face velocity shall be 100 fpm. It Includes a safety glass sash resistant to heat of up to 71 degrees centigrade. Static pressure loss is not to exceed 0.22 inches. The fume hood also has adjustable baffles. Other custom options are available. Used in laboratories to prepare samples requiring the use of toxic and or flammable materials.
-
L2250 - Hood, Fume, Bench
|Benchtop fumehood. This is an auxiliary air type to be sized as required. The unit will have a remote switch with a pilot light, a fluorescent light, an acid resistant fan and blower housing. The minimum average face velocity shall be 100 fpm. It shall include a steel frame sash that is heat resistant to 71 degrees centigrade. The static pressure loss shall not exceed 0.22 inches of water at 100 fpm face velocity. Other accessories and gases are as defined during the design of the facility.
-
L2270 - Hood, Fume, Radioisotope
|Radioisotope fumehood. The unit requires a charcoal trap filter, lead-lined or HEPA filter as required by codes and use criteria in the exhaust stack, not part of this hood. Other characteristics are that it be strong enough to support lead shielding bricks, have at least two duplex receptacles and a cup sink. The minimum average face velocity shall be 100 fpm and the static pressure loss through the hood shall not exceed 0.2 inches of water at 100 fpm face velocity (700 CFM).
-
L2275 - Hood, Fume, Radioisotope, Bench
|Bench type radioisotope fumehood. Characteristics/components include a glove-box, a 75 cfm. blower with indicating switch and variable speed power stat and manometer mounted on box front to indicate air flow, 1/4" safety glass viewing panel, three polarized and grounded electrical outlets with indicating switches, a 24 inch fluorescent light with fixtures and switch, two 8 inch double grooved glove ports and neoprene gloves, an inlet filter, two absolute filters with connecting hoses and 40 inches of 2 inch spiral exhaust hose with clamps and a variable height mobile bench, 30-37"H. Unit is customized to fit the specified use requirements.
-
L2280 - Hood, Laminar Flow, Horizontal, Free Standing
|Horizontal laminar flow hood. This is a freestanding unit that meets or exceeds Class 100 requirements set for Federal Standard 209B. The unit will have HEPA filters, a washable and reusable pre-filter, a work surface and side walls of type 304 stainless steel construction, duplex electrical receptacles, high velocity return air slots that provide an air curtain at the work area, work surface and side walls and blowers with an average velocity of 100 fpm. Used for work with non-hazardous materials where clean particle free air is required. 6 foot model, other sizes available.
-
L2290 - Hood, Laminar Flow, Horizontal, Bench To
|Bench top horizontal laminar flow fumehood. The unit meets or exceeds Class 100 requirements set for Federal Standard 209B. The unit characteristics/components are: HEPA filters, a washable and reusable pre-filter, work surface and side walls of type 304 stainless steel, duplex electrical receptacles, high velocity return air slots to provide an air curtain at the work area, work surface and side walls and a blower to provide an average velocity of 100 fpm. Used for work with non-hazardous materials where clean particle-free air is required. 4 Foot model represented, other sizes are available.
-
L2337 - Canopy, Hood, Fume
|Canopy fumehood. The unit includes a switched fan unit with pilot light; corrosion resistant steel, aluminum, or chemical resistant and fire retardant seamless fiberglass construction; dimensions as indicated on design drawings; fire suppression systems and any other special requirements to be defined during the facility design. It also includes a 3/4 horsepower motor blower. The static pressure loss shall not exceed 0.91 at 1290 cfm and 1.65 at 1935 cfm. It is equipped with baffles to maximize slot velocities and control fumes. Used in laboratories for low to moderate risk biological agents. Other sizes may be available. Blower motor mounted separate from the canopy and may not be included in the size specification.
-
L2339 - Hood, Fume, Histopathology Staining
|Histopathology staining fume hood to be used to contain manual and automatic staining stations. Double sliding doors permit access to entire height and half the width of the hood at one time. Integral fluorescent lighting provided for interior visibility. Unit provided with integral blower and hooks to building systems for exhaust to the atmosphere. Unit provides for front to back flow to protect technicians from volatile staining solution vapors. Base model is 30 inches wide but may be procured in widths up to 72 inches wide. Unit is designed to sit on existing bench tops.
-
120 CM CEILING HOOD
|Made from Anti-fingerprint stainless steel, the hood comes with dishwasher-safe professional greaseproof mesh filters.<b>The ceiling hood uses an external motor. Both products are sold separately. Please refer to your kitchen store to find out more about the optional KEMXX 00000 motor.<br>We also recommend to regularly change your hood filter to maintain the performances of your appliance. See below the reference of the hood filter that matches this ceiling hood.
-
60CM BUILT-IN EXTRACTOR HOOD
|This 60 cm built-in hood with traditional extraction mode has three extraction speeds plus a booster option and delayed stop function. The hood comes with dishwasher-safe professional greaseproof mesh filters.<b>We recommend to regularly change your hood filter to maintain the performances of your appliance. See below the reference of the hood filter that matches this 60 cm built-in hood.
-
cooker_hood_90_20180315
karma trendz | 1627390323Cooker Hood 90 cm
-
cooker_hood_60_20180315
karma trendz | 1627390347Cooker Hood 60 cm
-
RINNAI_COOKER_HOOD_RH_90ER_TS-180317
karma trendz | 1708693694Rinnai Cooker Hood RH 90ER
-
M0805 - Incubator, Infant, ICU, Mobile/Transport
|Mobile/transportable intensive care infant incubator. Unit consists of a closed controlled environment in a clear plastic hood for direct observation. Equipped with access ports, doors, heating and humidification systems, temperature and oxygen controllers, physiological monitoring system and a mattress. Used in the intensive care unit or for helicopter, airplane and ground ambulance movement of critically ill neonates. The services have approved different models and manufacturers. Verify airframe compatibility with Army Aeromedical Research Laboratory at Ft. Rucker or the US Air Force Armstrong Laboratory (AFMC) before purchasing.
-
M0810 - Incubator, Infant, ICU, Mobile
|ICU mobile infant incubator. Mobile unit consisting of a plastic hood enclosed controlled environment. Includes port access, on-door thermometer, oxygen port inlets, heating and humidification systems to create forced air circulation. To be used in the neonatal ICU to provide warm comfortable environments to premature neonates and critically ill newborns.
-
Siri 1
|Projector for outdoor applications; surface mounted (ceiling, wall, ground, stake); body in die-cast aluminium alloy EN AB 47100, screen in serigraphed, tempered glass; finishes: anthracite, white, cor-ten, grey; 2 power LEDs; 9W - 230Vac; built in power supply unit; includes 1,5 m neoprene cable, H05RN-F 3x1,0 Ø7 mm; total delivered lumens: 422 lm (3000K); optics: 6°, 12°, 30°, 40°, 10°x45°; LED colour: white - 2700K, 3000K, 4000K, 5000K; ingress protection: IP66; impact resistance: IK06; IPS built into the cable gland; operating temperature: -10°C +45°C; screen temperature: max 40°C (Ta 25°C); Glow wire test: 960°; photobiological safety: risk group 1 in accordance with EN62471:2006; appliance class: I; weight 0,80 kg; dimensions 240x84x48 mm; accessories: stake WP0300, honeycomb louvre WH5010, anthracite anti-glare hood WB5010H
-
Siri 2
|Projector for outdoor applications; surface mounted (ceiling, wall, ground, stake); body in die-cast aluminium alloy EN AB 47100, screen in serigraphed, tempered glass; finishes: anthracite, white, cor-ten, grey; 4 power LEDs; 16W - 230Vac; built in power supply unit; includes 1,5 m neoprene cable, H05RN-F 3x1,0 Ø7 mm; total delivered lumens: 925 lm (3000K); optics: 6°, 12°, 30°, 40°, 10°x45°; LED colour: white - 2700K, 3000K, 4000K, 5000K; ingress protection: IP66; impact resistance: IK06; IPS built into the cable gland; operating temperature: -10°C +45°C; screen temperature: max 40°C (Ta 25°C); Glow wire test: 960°; photobiological safety: risk group 1 in accordance with EN62471:2006; appliance class: I; weight 1,60 kg; dimensions 254x123x48 mm; accessories: stake WP0300, honeycomb louvre WH5020, anthracite anti-glare hood WB5020H
-
Siri 3
|Projector for outdoor applications; surface mounted (ceiling, wall, ground, stake); body in die-cast aluminium alloy EN AB 47100, screen in serigraphed, tempered glass; finishes: anthracite, white, cor-ten, grey; 9 power LEDs; 23W - 230Vac; built in power supply unit; includes 1,5 m neoprene cable, H05RN-F 3x1,0 Ø7 mm; total delivered lumens: 1491 lm (3000K); optics: 6°, 12°, 30°, 40°, 10°x45°; LED colour: white - 2700K, 3000K, 4000K, 5000K; ingress protection: IP66; impact resistance: IK06; IPS built into the cable gland; operating temperature: -10°C +45°C; screen temperature: max 40°C (Ta 25°C); Glow wire test: 960°; photobiological safety: risk group 1 in accordance with EN62471:2006; appliance class: I; weight 2,10 kg; dimensions 283x170x48 mm; dimming with 0-10V; accessories: stake WP0300, honeycomb louvre WH5030, anthracite anti-glare hood WB5030H